白内障手术前后前房改变的超声生物显微镜量化测量及眼压变化规律的观察与意义

To Evaluate the Significance and Study the Changes of Anterior Chamber Quantitatively Measured by Using Ultrasound Biomicroscopy and Observe the Changes of Intraocular Pressure before and after Cataract Surgery

【作者】 胡蓉

【导师】 贾松柏;

【作者基本信息】 中南大学 , 眼科学, 2007, 硕士

【摘要】 目的:通过采用超声生物显微镜(UBM)对白内障手术前后前房的量化测量与比较以及对白内障手术前后眼压变化情况的观察,探讨前房形态及眼压的变化规律与意义。方法:对50例(50只眼)老年性白内障患者,均行超声乳化白内障吸除联合折叠式人工晶状体植入术,分别于术前和术后1、2、3个月用超声生物显微镜量化测量前房深度和前房角宽度,观察人工晶体位置并于术后1、3、7、15天,1、2、3月测量眼压及视力,观察眼部并发症。结果:1、全部患者术后1、2、3月时前房深度(ACD)、500μm处小梁虹膜夹角(TIA500)、500μm和250μm处前房角开放距离(AOD500、AOD250)、小梁睫状体距离(TCPD)、巩膜睫状体夹角(CPSA)与术前比较均显著增大,且均有显著性差异(P<0.05)。2、术后1月、2月和3月时,上述各值相互比较均无显著性差异(P>0.05)。3、术后眼压比术前均有一定程度下降,前者与后者比较有显著性差异(P<0.05),术后各时间点眼压相互比较,均无显著性差异(P>0.05)。4.术后视力明显优于术前(P<0.05),人工晶体都位于囊袋内,均未见严重并发症。结论:1、超声乳化白内障吸除联合折叠式人工晶状体植入术后的前房与术前相比,前房明显加深,房角明显加宽,且在术后一月基本稳定。2、超声乳化白内障吸除联合折叠式人工晶状体植入术能明显降低眼内压。

【Abstract】 Objective: To quantitatively measure and compare the changes of anterior chamber by using ultrasound biomicroscopy, and to observe the changes of intraocular pressure before and after cataract surgery, discussing the change law and the significance of anterior chamber morphological features and intraocular pressure.Methods: The operation of phacoemulsification and foldable IOL implantation were performed in 50 eyes of 50 senior cataract patients .The depth of anterior chamber and the width of anterior chamber angle were determined quantitatively and the position of the intraocular lenses was discovered by using ultrasound biomicroscopy before and 1st、2nd、3rd month after the surgery. The visual acuity and intraocular pressure were measured in 1st、3rd、7th、15th day and 1st、2nd、3rd month after the surgery. The ocular complications were discovered at the same time.Results:1.In all patients , there was significant difference( P <0.05) of ACD (anterior chamber distance),TIA500 (trabecular-iris angle at 500μm from the scleral spur), AOD500 (angle- opening distance at 500μm from the scleral spur) and AOD250 (angle-opening distance at 250μm from the scleral spur) , TCPD ( trabecular-ciliary processes distance ), CPSA(ciliary-scleral angle) among 1st、2nd、3rd month pre-operation and post-operation .And they were all increased significantly after the operation.2. There was no significant difference (P>0.05) of above -mentioned measurements among the 1st、2nd、3rd month after surgery.3.The intraocular pressure of post-operation was lower than pre-operation and there was significant difference( P <0.05) between them. But there was no significant difference (P > 0.05) among the each time points post-operation.4. The postoperative visual acuity was significantly better than preoperative visual acuity( P< 0.05).All intraocular lenses were implanted in the bag and shown the well symmetrical in posterior chamber. Serious ocular complications were not discovered after surgery.Conclusions:1. The anterior chamber angle was widened and the anterior chamber distance was deepened significantly after the operation of phacoemulsification and foldable IOL implantation. The measurements kept stable on 1st month after surgery.2. The intraocular pressure was also reduced to some extent after this surgery.

  • 【网络出版投稿人】 中南大学
  • 【网络出版年期】2009年 01期
  • 【分类号】R779.66
  • 【被引频次】3
  • 【下载频次】172
节点文献中: 

本文链接的文献网络图示:

本文的引文网络