闪烁伽马能谱仪全谱数据的蒙特卡罗模拟

The Modeling of Full Spectrum Data of the Scintillation Gamma-ray Spectrometer by Monte Carlo

【作者】 储星铭

【导师】 王南萍;

【作者基本信息】 中国地质大学(北京) , 地球探测与信息技术, 2008, 硕士

【摘要】 多道γ能谱测量在电离辐射环境评价或放射性污染检测中是高效准确的方法,自1986年切尔诺贝利核电站事故以来得到了广泛的应用。NaI(Tl)伽马能谱仪具有探测效率高、可在常温下使用等特点,在航空和现场能谱测量中应用广泛,但是其晶体能量分辨率不高,导致人工核素137Cs的全能峰与238U系214Bi和232Bi和232Th系208Tl的峰重叠,提取人工核素铯比较困难。因此,研究如何快速、准确地提取人工核素137Cs的有用信息,对提高NaI(Tl)闪烁体探测器伽马能谱测量资料的定量解释精度具有重要意义。本论文应用蒙特卡罗方法,利用MCNP程序对DigiDART碘化钠伽马能谱仪测量的土壤天然放射性核素238U、232Th、40K及人工放射性核素137Cs进行了定量分析。论文在前人基础上对仪器探测效率重新进行了计算,并得到了仪器探测效率的响应函数。在模拟过程中修改了探测器的几何构造以及物质组成,使模拟的仪器设备参数更符合真实仪器。模拟了137Cs点源的模拟谱线,通过增加模拟时间提高了模拟数据的精度。模拟谱线比实测谱线在低能端较低,两者主峰位吻合较好,两者峰面积的相对误差在30%以内。体源模拟加入了更多核素的能量,提高了低能端的康普顿散射计数。同时,考虑了光电效应以及电子对效应,使得模拟结果能更接近真实测量值。通过学习研究模拟值归一方法,修改了扩展因子,使得模拟谱线更接近实测谱线。高于583keV的特征峰模拟数值与实测谱线的特征峰数值相近,误差在20%以内。低于583keV的几个特征峰的康普顿散射坪低于实测值,但主峰位对应较好。

【Abstract】 Multi-channelγspectrum of ionizing radiation measurements in the environmental assessment or detection of radioactive contamination is highly efficient and accurate way, since the 1986 Chernobyl accident has been widely used. NaI (Tl) gamma-ray spectrometer with high efficiency, can be used at room temperature, and other characteristics, in the air and in-site measurements in the application of broad spectrum, but its crystal energy resolution is not high, leading to artificial radionuclide the 137Cs And 238U of 214Bi and 232Bi and 232Th peak of 208Tl overlap, artificial isotope cesium extraction more difficult. Therefore, how quickly and accurately extract of the radionuclide 137Cs useful information to enhance NaI (Tl) scintillator detector gamma-ray spectrometry quantitative data to explain the importance of accuracy.This paper applications Monte Carlo method, using MCNP procedures DigiDART sodium iodide gamma-ray spectrometer measurement of the soil natural radionuclides 238U, 232Th, 40K and artificial radionuclides 137Cs for the quantitative analysis.In previous papers on the basis of the efficiency of detection equipment were re-calculated, and with the efficiency of detection equipment response function. In the simulation process of amending the geometry of the probe and the material composition, laboratory equipment closer to the real equipment.Simulation of the 137Cs point source from the detector 10 cm from the analog spectrum, by increasing the simulation time to improve the accuracy of the simulation data. Analog spectrum than measured in the low-low spectrum, the two main peak in good agreement, the two relative error of 30 %.Yuen joined the simulation of the radionuclide more energy to raise the low end of the Compton scattering count. At the same time, consider the photoelectric effect and electronic effects, makes simulation results can be closer to the real measurement. Through the study on a method to the value of simulation, amended the expansion factor, makes analog spectrum close to the measured spectrum. More than 583keV numerical simulation of the characteristic peaks and measured the spectrum characteristic peak values similar error at 20%. 583keV below the peak of several features of Compton scattering Ping lower than the actual value, but peak corresponds better.

【关键词】 MCNPNaI(Tl)137Cs模拟
【Key words】 MCNPNaI(Tl)137CsSimulation
  • 【分类号】P631.6
  • 【被引频次】3
  • 【下载频次】538
节点文献中: 

本文链接的文献网络图示:

本文的引文网络