节点文献

冰岛Laugaland地热田示踪试验与回灌温度模拟

Prediction of Injection Induced Cooling Based on Analysis of Tracer Test Data in the Laugaland Geothermal Field,S-Iceland

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张远东魏加华

【Author】 ZHANG Yuan-Dong~1 WEI Jia-Hua~2(1 Institute of Geology and Geophysics,Chinese Academy of Sciences,Beijing 100029,China;2 Department of Hydraulic and Hydropower Engineering,Tsinghua University,Beijing 100084,China)

【机构】 中国科学院地质与地球物理研究所清华大学水利水电工程系 北京100029北京100084

【摘要】 开采井温度下降是热储回灌实施过程中的潜在问题之一.在冰岛Laugaland地热田研究过程中,为评价和预测回灌后热储温度的变化,采用示踪试验方法定量研究采、灌井之间的水力联系.示踪数据的解译分析表明,采、灌井之间的水力联系密切.基于示踪试验,对不同的采、灌量条件所引起的开采井温度变化进行了定量模拟.模拟结果与实测温度之间存在一定的偏差,主要原因可能是示踪试验阶段和实施回灌时热储中水动力条件存在差异所致.此外,该区的两次地震也可能在一定程度上改变了热储中水流运动模式.

【Abstract】 The temperature decline of production wells is a potential problem induced by reinjection.At Laugaland,in order to assess and predict the temperature changes resulting from reinjection,a tracer test was carried out as an effective tool for quantitatively studying the hydraulic connection between production and injection wells.The analysis of the tracer test data indicates that the connection between the injection well GN-1 and production well LWN-4 is fairly direct.Based on the tracer test,the reinjection-induced temperature decline of the production well LWN-4 was predicted under different hypotheses and production-reinjection scenarios.The calculated temperature decline is,however,a few degrees greater than the actual cooling observed.The discrepancy is mainly attributed to a drastic change in flow conditions because of reduced production since reinjection started.In addition,the major earthquakes in 2000 may also have influenced the flow-pattern in the reservoir at Laugaland.

【关键词】 地热田回灌示踪试验温度Laugaland冰岛
【Key words】 geothermal fieldreinjectiontracer testtemperatureLaugalandIceland
  • 【文献出处】 中国科学院研究生院学报 ,Journal of the Graduate School of the Chinese Academy of Science , 编辑部邮箱 ,2005年06期
  • 【分类号】P314
  • 【被引频次】10
  • 【下载频次】203
节点文献中: 

本文链接的文献网络图示:

本文的引文网络