循环荷载下高温冻土的变形和强度特性

Deformation and strength of warm frozen soils under cyclic loading

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 焦贵德赵淑萍马巍罗飞孔祥兵

【Author】 JIAO Gui-de 1,2,3,ZHAO Shu-ping 1,MA Wei 1,LUO Fei 1,KONG Xiang-bing 1(1.State Key Laboratory of Frozen Soil Engineering,Cold and Arid Regions Environmental and Engineering Research Institute,Chinese Academy of Sciences,Lanzhou 730000,China;2.Key Laboratory of Mechanics on Disaster and Environment in Western China Attached to the Ministry of Education of China,Lanzhou University,Lanzhou 730000,China;3.School of Civil Engineering and Mechanics,Lanzhou University,Lanzhou 730000,China)

【机构】 中国科学院寒区旱区环境与工程研究所冻土工程国家重点实验室兰州大学西部灾害与环境力学教育部重点实验室兰州大学土木工程与力学学院

【摘要】 对-1℃的冻土试样在频率为3,5,8 Hz的循环荷载下进行了单轴压缩试验,探讨了冻土在循环荷载下的累积变形和动强度。结果表明:循环荷载作用下冻土的累积变形大小由加载的最大动应力大小决定,同一频率下加载的最大动应力越大,相同循环次数时的累积应变越大;根据加载的最大动应力的大小,累积应变与循环次数的关系曲线可表现为破坏型、稳定型和过渡型3种形态之一。加载频率对冻土累积应变的影响规律复杂,且受加载的最大动应力影响;当最大动应力较小时,频率的影响不明显;当最大动应力比较适中时,大体上频率越高,累积应变越大;当最大动应力比较大时,频率越高,累积应变越小。在3%,5%和10%的破坏应变下,频率为8 Hz时冻土的动强度最大,而3 Hz和5 Hz的动强度比较接近。

【Abstract】 The uniaxial compression tests on frozen soils under-1℃ and cyclic loading are carried out.The vibration frequencies are 3,5 and 8 Hz.The cumulative deformation and dynamic strength of the frozen soils under cyclic loading are studied.The results show that the cumulative deformation of the frozen soils under cyclic loading is dependent on the maximum cyclic stress.When the frequency is the same,the larger the maximum cyclic stress,the larger the cumulative strain.According to the maximum cyclic stress,the changing curves of the cumulative strain with cyclic number can be divided into failure type,stable type and transition type.The loading frequency affects the cumulative strain in a complex way.When the maximum cyclic stress is small,the frequency has slight effect on the cumulative strain.When the maximum cyclic stress is moderate,on the whole,the higher the frequency,the greater the cumulative strain.When the maximum cyclic stress is large,the higher the frequency,the smaller the cumulative strain.When the failure strains are 3%,5% and 10%,the dynamic strength is the greatest under loading frequency of 8 Hz,and the dynamic strength under 3 Hz is close to that under 5 Hz.

【基金】 国家自然科学基金项目(41023003,40971046);国家自然科学基金创新群体项目(41121061)
  • 【文献出处】 岩土工程学报 ,Chinese Journal of Geotechnical Engineering , 编辑部邮箱 ,2013年08期
  • 【分类号】TU445
  • 【网络出版时间】2013-04-25 11:00
  • 【被引频次】7
  • 【下载频次】417