节点文献

基于FPGA的低功耗无缆地震仪校钟系统

Time Correcting System of Cable-less Seismograph Based on FPGA in Low-power Consumption

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李君辉陈祖斌申茂冬朱亚东洋庞广华

【Author】 LI Jun-hui;CHEN Zu-bin;SHEN Mao-dong;ZHU Ya-dong-yang;PANG Guang-hua;College of Instrumentation and Electrical Engineering,Jilin University;

【机构】 吉林大学仪器科学与电气工程学院

【摘要】 为了降低当前无缆地震仪的功耗,并且提高其同步采集的精度,文中采用定时开启GPS,利用GPS输出的1 PPS脉冲校准采集站内置32.768 MHz恒温晶振,将校正输出的秒分频信号作为无缆地震仪采集站的同步时标。同时,利用GPS接收机输出的UTC信息校正采集站内部时钟,从而达到低功耗校钟的目的。

【Abstract】 To reduce the power consumption and improve the synchronous acquisition accuracy of the current cable-less seismograph. This paper opened GPS regularly,used the GPS 1PPS output to correct 32. 768 MHz OCXO in acquisition station. The corrected outputs of the divided second signals served as the synchronization time scale for acquisition stations of cable-less seismograph. The universal time coordinated information from GPS receiver was used to correct the internal clock of acquisition station.The system achieved the purpose of correcting the clock in low-power consumption.

【基金】 国家深部探测专项(201011081);无缆自定位地震勘探系统研制(SinoProbe-0904)
  • 【文献出处】 仪表技术与传感器 ,Instrument Technique and Sensor , 编辑部邮箱 ,2014年11期
  • 【分类号】TH763
  • 【被引频次】4
  • 【下载频次】61
节点文献中: 

本文链接的文献网络图示:

本文的引文网络