【作者】 廖耘容柏生李盛勇

【Author】 Liao Yun;Rong Baisheng;Li Shengyong;RBS Architecture Engineering Design Associates;

【机构】 广州容柏生建筑结构设计事务所

【摘要】 通过某个简单的示例模型,阐述《高层建筑混凝土结构技术规程》(JGJ 3—2010)中剪力墙轴压比计算方法在200m以上超高层建筑设计中存在的问题,主要有不考虑翼缘墙和腹板墙的区别、不同抗震设防烈度的区别、不同倾覆弯矩分担比例的区别等问题。同时给出了轴压比计算时考虑地震作用设计值和长墙轴压比计算中考虑弯矩影响这两个改进建议。

【Abstract】 A simple example was used to show the problems in calculation of shearwall axial compression ratio for super high-rise buildings over 200 m according to Technical specification for concrete structures of tall building( JGJ 3—2010),such as discarding the difference between the flange wall and web wall,different seismic precautionary intensities and different sharing proportion of overturning moment. Two suggestions were offered to improve the calculation,including considering seismic design load in axial compression ratio calculation and considering moment effect in long shearwall axial compression ratio calculation.

  • 【文献出处】 建筑结构 ,Building Structure , 编辑部邮箱 ,2015年07期
  • 【分类号】TU973.16