大庆乙烯分厂医院砖砌体结构楼房的抗震加固
Analysis on Seismic Reinforcement for the Masonry Structure of a Hospital in Daqing City
【摘要】 针对位于6度区的大庆乙烯分厂医院主楼砖砌体楼房抗震能力不足的问题,采用设置构造柱和混凝 土抗震墙、连接圈梁、封闭开口墙体、锚固女儿墙等加固方法,增加了结构的整体抗震性能。加固后6年多的使 用表明加固效果良好。
【Abstract】 Some seismic fortification measures were adopted to strengthen the mansory structure of a hospital in 6 intencity area,such as setting structureal columns and shear walls,enclosing beams and ringent walls,anchoring cantilever walls.The good performance of 6 years after reinforcing indicated that the integral seismic behavior of the building is satisfactory.
- 【文献出处】 建筑结构 ,Building Structure , 编辑部邮箱 ,2005年03期
- 【分类号】TU364
- 【被引频次】1
- 【下载频次】63