节点文献

PM2.5中OC/EC测定的离线分析法与在线分析法比较

Comparison of Off-line Analysis and On-line Analysis for Organic Carbon and Elemental Carbon in PM2.5

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘琼玉谈静钟章雄龚海群胡珂梁胜文米铁

【Author】 LIU Qiongyu;TAN Jing;ZHONG Zhangxiong;GONG Haiqun;HU Ke;LIANG Shengwen;MI Tie;Hubei Key Laboratory of Industrial Fume and Dust Pollution Control,Jianghan University;Wuhan Environmental Monitoring Centre;

【机构】 工业烟尘污染控制湖北省重点实验室(江汉大学)武汉市环境监测中心

【摘要】 采用离线分析法和在线分析法同步监测了武汉市PM2.5中有机碳(OC)、元素碳(EC)和总碳(TC)的浓度,分析了2种方法的差别。结果表明,离线分析法与在线分析法对TC的测定结果具有很好的可比性,2种方法对TC的测定结果显著相关(r=0.970 9)。离线分析法得到的OC浓度普遍高于在线分析法,前者为后者的1.12倍,造成OC结果差异的主要原因可能是采样系统的差异。2种方法对EC测定的相关性较低(r=0.763 0),且2种方法对EC测定的精密度(相对偏差为13.14%)也不如其对TC和OC测定的精密度(相对偏差分别为3.42%和5.95%),造成EC结果差异的原因较复杂。离线分析法测得的OC/EC值明显高于在线分析法,鉴于OC/EC值在颗粒物源解析研究中具有重要意义,需要规范OC/EC分析方法。

【Abstract】 The concentration of organic carbon(OC), elemental carbon(EC) and total carbon(TC) in fine particulate matter(PM2.5) of Wuhan city were simultaneously analyzed by off-line analysis and on-line analysis methods. The differences between the results of these two methods were compared. The results showed that the concentration of total carbon(TC) was well correlated with off-line analysis and on-line analysis, with the correlation coefficients r was 0.9709, these two methods were in good agreement with TC determination. The concentration of OC obtained by off-line analysis was generally higher than that of OC obtained by on-line analysis, with the former was 1.12 times higher than the latter. The main reason that the results of OC obtained by off-line analysis was higher than on-line analysis may be due to the difference of sampling system. The correlation between these two methods for EC determination was lower(r=0.7630), and the precision(relative deviation was 13.14%) of these two methods for EC determination was also lower than that for TC and OC determination(relative deviations were 3.42% and 5.95%, respectively). The reasons for the differences in EC results were more complicated. The OC/EC ratio measured by off-line analysis method was obviously higher than on-line analysis method. In view of the significance of OC/EC ratio in source apportionment of particulates, it is need to standardize the OC/EC analysis method.

【基金】 湖北省高等学校优秀中青年科技创新团队项目(T201420);武汉研究院开放性课题资助项目(IWHS2016332)
  • 【文献出处】 中国环境监测 ,Environmental Monitoring in China , 编辑部邮箱 ,2019年04期
  • 【分类号】X831
  • 【网络出版时间】2019-07-23 11:10
  • 【被引频次】2
  • 【下载频次】234
节点文献中: 

本文链接的文献网络图示:

本文的引文网络