节点文献

龙岩地震台GM4型磁通门磁力仪典型干扰分析

The Typical Interference of GM4 Fluxgate Magnetometer in Longyan Seismic Station

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杨佩琴刘其寿王绍然黄鹤凌郑永通

【Author】 YANG Pei-qin1,LIU Qi-shou1,WANG Shao-ran1,HUANG He-ling2,ZHENG Yong-tong1(1.Longyan Seismic Station of FuJian Province,Longyan 364000,China;2.Shaowu Seismic Station of FuJian Province,Shaowu 354000,China)

【机构】 福建省龙岩地震台福建省邵武地震台

【摘要】 GM4型磁通门磁力仪是"十五"项目中地磁学科主要仪器。龙岩台GM4型磁通门磁力仪主要受到来自铁磁性物质和电磁类型的干扰。由已知干扰类型,对记录曲线典型畸变形态进行对比、分析、总结,可以更好分辨干扰,进行恰当、合理、准确地预处理,保证数据的连续、可靠、精确。

【Abstract】 GM4 fluxgate magnetometer is the main equipment of geomagnetism in the "Tenth-five year project",the interferences to which are mostly of iron magnetic material and electromagnetic types.According to the given interference types,distortion of observation data is contrasted,analyzed and summarized so as to distinguish and preprocess interferences appropriately,keep the observation as consistent,reliable and accurate as possible.

【关键词】 GM4铁磁性物质电磁类型干扰
【Key words】 GM4iron magnetic materialelectromagnetic typesinterference
  • 【文献出处】 华北地震科学 ,North China Earthquake Sciences , 编辑部邮箱 ,2010年04期
  • 【分类号】P315.62
  • 【下载频次】56