节点文献

多高层钢结构最佳侧移刚度分布与最佳截面惯性矩分布研究

Study on Optimum Lateral Stiffness Ratio and Optimum Moment of Inertia Ratio for Multistorey Steel Structure

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王星星裴星洙王维

【Author】 Wang Xing-xing,Pei Xing-zhu,Wang Wei(School of Civil Engineering & Architecture,Jiangsu University of Science and Technology,Zhenjiang 212003,China)

【机构】 江苏科技大学土木与建筑工程学院

【摘要】 以多高层钢结构在罕遇地震作用下各层的累积塑性变形倍率相等为目标,探讨了多高层钢结构的最佳侧移刚度分布和最佳截面惯性矩分布。建立6层、9层、12层钢框架结构算例模型,利用时程分析法对其进行动力弹塑性时程分析,计算出算例模型各层的累积塑性变形倍率。不断调整算例模型各层的侧移刚度,使算例模型在地震作用下各层的累积塑性变形倍率相等。将此时算例模型各层的侧移刚度与底层侧移刚度的比值称为最佳侧移刚度比。以最佳侧移刚度比为目标,对算例模型进行静力弹塑性分析,各层梁的惯性矩取为底层柱的1/10,调整算例模型各层柱截面的惯性矩,使算例模型的侧移刚度比刚好满足最佳侧移刚度比,将此时结构各层柱截面的惯性矩与底层柱截面的惯性矩之比定义为最佳截面惯性矩比。最后,用一个7层算例模型验证了最佳侧移刚度比和最佳截面惯性矩比的合理性。

【Abstract】 In order to study the optimum lateral stiffness ratio and optimum moment of inertia ratio of steel structure,three steel-frame models(6,9,12storey) are designed.Time history method is used to study the earthquake response of the three models.Lateral stiffness of each model is changed to make the cumulative plastic deformation rate of each storey equal.When the cumulative plastic deformation rate of each storey is equal,the ratio of each lateral stiffness and the first storey lateral stiffness of each model is called optimum stiffneness ratio,the ratio of the number of each storey and the total number of the storeies is called the storey ratio.The function between the optimum stiffness and the storey ratio is given using the optimum stiffness ratio and the storey ratio of the three designed models.Optimum moment of inertia ratio is studied using the push-over method under the assumption of optimum lateral stiffness ratio.The function is the criteria that we used to design the steel-frame structure.In order to prove the validity of the function,a 7-storey steel-frame model is designed,which used the optimum stiffness ratio and the liner stiffness ratio respectively.It shows that the cumutive plastic deformation rates of the structure using the optimum stiffness ratio are most the same,which is better than that of the structure using the liner stiffness ratio.

  • 【文献出处】 工程抗震与加固改造 ,Earthquake Resistant Engineering and Retrofitting , 编辑部邮箱 ,2011年01期
  • 【分类号】TU391
  • 【被引频次】7