节点文献

耗能减震结构中耗能器总耗能层间分配比例研究

Rearch on the Total Energy Consumption Ratio of Dampers between Stories in Passive Energy Dissipation Structures

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 乐登周云邓雪松

【Author】 Yu Deng,Zhou Yun,Deng Xue-song(School of Civil Engineering of Guangzhou University,Guangzhou 510006,China)

【机构】 广州大学土木工程学院

【摘要】 对于沿层高方向均匀布置耗能器的耗能减震结构,耗能器总耗能各层间分配比例的合理估计是耗能减震结构基于能量的设计方法需解决的问题之一。本文以3层7、层、12层均匀布置不同类型耗能器的混凝土框架结构为例,分析了地震动幅值对层间分配比例的影响,结果表明,线性粘滞阻尼器总耗能的层间分配比例不受地震动幅值的影响,非线性粘滞阻尼器和金属耗能器总耗能各层间分配比例受地震动幅值影响较小,可忽略不计。以一受正弦函数激励作用的均匀布置耗能器的多自由度系统为研究对象,推导了不同类型耗能器总耗能各层间分配比例的近似计算公式,以8条不同场地类型地震波为输入,分别对3层、7层1、2层附加不同类型耗能器的结构进行时程分析。采用近似计算公式的计算值与时程分析值的对比表明,线性粘滞阻尼器总耗能层间分配比例近似值与时程分析值吻合较好,非线性粘滞阻尼器和金属耗能器总耗能各层间分配比例近似值与时程分析值差别不大,在基于能量的设计中可采用近似值估计分配比例值。

【Abstract】 For the damping absorption energy structure with dampers uniform layout along the direction of the height,to estimate the total energy consumption of dampers distributed between stories rational is one of the issues to be resloved for the design based on energy.In this paper,taking 3 stories,7 stories,12 stories of concrete framework with different types of dampers uniform layout as an example the impact of the seismic amplitude to the ratio between the stories studied.The results showe that the ratio of the total energy distributed between stories for the linear viscous damper is irrelevant while small for the nonlinear viscous damper and metal damper.so it can be ignored.With a sine function stimulation of many-degree-of-freedom systerm that uniform layout dampers to study,the approximate caculation formulas of the ratio between stories about the total energy of dampers are Devived.By inputting 8 seismic waves of different types land,the example structure with different dampers is analyzed.The comparison between the caculated values with approximate formula and the actual value shows that the ratio of total energy consumption between caculated value and actual value is good agreement for linear viscous dampers,while there is small difference for nonlinear viscous dampers and metal dampers.It can be estimate value of the ratio for actual use while design based on energy.

【基金】 国家自然科学基金(50678040);广东省自然科学基金团队项目(8351009101000001);建设部科技攻关项目(02-2-1.25)
  • 【文献出处】 工程抗震与加固改造 ,Earthquake Resistant Engineering and Retrofitting , 编辑部邮箱 ,2009年03期
  • 【分类号】TU352.1
  • 【被引频次】9
  • 【下载频次】331
节点文献中: 

本文链接的文献网络图示:

本文的引文网络