节点文献

三门核电站弹塑性时程分析

Elastoplastic Time-history Analysis of San Men Nuclear Power Station

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 潘宇吕令毅束磊周建章张建成林少波

【Author】 PAN Yu1,LV Ling-yi1 ,SHU Lei1,ZHOU Jian-zhang2,ZHANG Jian-cheng2,LIN Shao-bo2 (1.Key Laboratory for RC&PC Structure Education Ministry Southeast University,Nanjing 210096,China;2.East China Electric Power Design Institute,Shanghai 200063,China)

【机构】 东南大学土木工程学院RC&PC教育部重点实验室华东电力设计院

【摘要】 三门核电站主厂房为大跨度钢框架结构,采用有限元分析程序ANSYS对主厂房整体结构进行模态分析和弹塑性时程分析。通过其固有振动周期和振型,对结构的振动特性有简单的认识。根据分析结果对三门核电站主厂房的抗震性能进行评估,认为结构在相同场地条件下具有良好的抗震性能。

【Abstract】 SAN Men nuclear power station is a long-span steel frame structure. Modal analysis and elastoplastic time-history analysis for the integral structure are carried out with finite element analysis program ANSYS. Through its natural vibration periods and mode shapes,a simple understanding of the vibration characteristics is fond. Based on the results of the elastoplastic time-history analysis,the sesmic of the integral structure of the SAN Men nuclear power station is evaluated,and it is showen that the sesmic performance of the structure in the same site condition is well.

【基金】 973计划资助项目(No2007CB714200);教育博士点基金资助(No20070286017)
  • 【文献出处】 工程建设与设计 ,Construction & Design for Project , 编辑部邮箱 ,2010年02期
  • 【分类号】TU393.3;TU313
  • 【被引频次】2
  • 【下载频次】113
节点文献中: 

本文链接的文献网络图示:

本文的引文网络