超大型钢筋混凝土冷却塔模型地震模拟振动台试验研究

Shaking table test for the 1/30 model of a super huge R/C cooling tower

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 翁旭然戴君武胡扬

【Author】 WENG Xu-ran,DAI Jun-wu,HU Yang(Key Laboratory of Earthquake Engineering and Engineering Vibration,China Earthquake Administration, Harbin,Heilongjiang 150000,China)

【机构】 中国地震局地震工程与工程振动重点实验室

【摘要】 研究原型结构为即将要在抗震设防烈度8度区建设的高度为220 m的1 000 MW级热力发电厂超大型间接空气冷却塔,设计并实现了缩尺比为1∶30模型的地震模拟振动台试验.试验工况涵盖I~IV类场地条件下,冷却塔模型分别在7度、8度设防多遇地震、偶遇地震和罕遇地震对应的72组三向地震动激励,观察检验模型结构在不同场地条件不同地震动激励水平下的反应性态.同时,在每个级别的地震模拟试验工况前后,进行模型振动模态特性试验,实时监控模型结构在经历每个阶段地震动工况后的振动特性变化情况.试验结果表明,该冷却塔结构基本能够满足7度、8度设防条件下的抗震要求,但冷却塔下部的X型支腿两端与其喉部以上的壳体属于抗震薄弱部位,受较为密集的多个相邻高阶振型耦合振动影响,上部壳体厚度最薄处出现较为严重的环向破坏.

【Abstract】 The 1/30 scaled model of a cooling tower was designed and tested in a shaking table in this study,whose prototype structure is a 220 m high super huge indirect dry cooling tower(1 000 MW grade) of an electric power project which will be constructed in an area of fortify intensity 8.The test contained 72 cases that the model structure was orderly excited by minor earthquake,moderate earthquake and major earthquake under seismic fortify intensities of 7 and 8 in four different site conditions(I~IV).Meanwhile,white noise excitation tests were inserted before and after each condition to real-time monitor changes of model structure’s natural vibration characteristics.The results show that,the cooling tower can basically satisfy anti-seismic requirements under the fortifying intensity 7 and 8,but the two ends of the X-pillar and the shell above the throat of the tower are both the weak parts.In addition,due to the influence of multiple adjacent high modes’ coupled vibration,severe hoop damage may appear at the thinnest shell of the tower.

【基金】 国家国际科技合作专项基金资助项目(2012DFA70810)
  • 【文献出处】 福州大学学报(自然科学版) ,Journal of Fuzhou University(Natural Science Edition) , 编辑部邮箱 ,2013年04期
  • 【分类号】TU375;TU317
  • 【网络出版时间】2013-07-08 16:05
  • 【被引频次】6
  • 【下载频次】135
节点文献中: 

本文链接的文献网络图示:

本文的引文网络