伸缩仪标定故障解决实例

Case study of extensometer calibration faults and solutions

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 朱石军赵帅马广庆徐绿清

【Author】 Zhu Shijun;Zhao Shuai;Ma Guangqing;Xu Lvqing;Yanqing Seismic Station;Earthquake Administration of Beijing Municipality;Earthquake Administration of Hebei Province;

【机构】 延庆地震台北京市地震局河北省地震局

【摘要】 延庆地震台伸缩仪在2011年9月和2013年3月两次标定过程中,EW分量和NS分量分别出现标定不合格问题,经过分析排查,最终通过维修标定器解决故障。此类问题从标定数据看有一定规律性,故障现象具有典型性,对地震台站伸缩仪运行维护和故障判定具有借鉴意义。

【Abstract】 The EW component and NS component of the extensometer at Yanqing Seismic Station were calibrated unqualified in Sep.2011 and Mar.2013,respectively.After been investigated and analyzed,the issues were ultimately resolved by repairing designator.With certain regularity on calibration data and the typicality on faults,these issues are good references to extensometer operating maintenance and fault judging for seismic stations.

【关键词】 伸缩仪标定故障仪器维护
【Key words】 extensometercalibration faultsequipment maintenance