节点文献

LN-3A水位仪记录的高采样率大震水震波特点及仪器改进

Features of digital high sampling rate water-seismic wave about large earthquakes recorded by LN-3A water-level meter and suggestions for improvement of water-level meter

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 顾申宜明穗花黄启立张慧解晓静叶向顶刘阳

【Author】 Gu Shenyi~(1)),Ming Suihua~(1)),Huang Qili~(2)),Zhang Hui~(1)),Xie Xiaojing~(1)),Ye Xiangding~(1)) and Liu Yang~(1)) 1) Earthquake Administration of Hainan Province,Haikou 570203,China 2) Technology and Information Industry Bureau of Danzhou,Hainan Province 571700,China

【机构】 海南省地震局儋州市科技与信息产业局

【摘要】 分析了海南前兆台网水位仪对苏门答腊M_S 8.7地震和我国四川汶川Ms 8.0地震的高采样率水震波记录情况,从中可较明显地看到地震波引起的井水位详细变化,但也存在水震波的丢头、仪器时间存在误差,第一代仪器水震波相互覆盖等现象,提出了在水位仪中增加在线缓存记录、自动定时校时功能等改进建议。

【Abstract】 The high sampling rate water-seismic waves about Sumatra-Andeman strong earthquakes and Wenchuan earthquake recorded by water-level meter of Hainan digital seismic precursor network were analyzed.The detailed variations of well water-level caused by seismic waves can be distinguished from the water-seismic waves.But there were some problems, such as the heads of water-seismic waves were missed recording, time errors of water-level meter relatively great and water-seismic waves recorded by the first generation water-level meter sometimes were covered each other.The some improvements: such as adding function of data online cache and automatic correcting time in water-level meter were put forward.

【基金】 2009年度“地震监测预报科研三结合”课题
  • 【文献出处】 地震地磁观测与研究 ,Seismological and Geomagnetic Observation and Research , 编辑部邮箱 ,2010年02期
  • 【分类号】P315.62
  • 【被引频次】3
  • 【下载频次】8
节点文献中: 

本文链接的文献网络图示:

本文的引文网络