【摘要】 本文对柬埔寨达岱河水电站主坝、副坝面板的裂缝成因进行了分析,根据裂缝的分类提出了针对性的处理措施。通过采用止水材料、化学灌浆材料、防渗涂料等,取得了较好的处理效果,为同类型项目混凝土面板裂缝防渗处理提供了较好的借鉴。
【Abstract】 Analysis was made on the causes for the cracks in the concrete face slab of main dam and auxiliary dam of Stung Tatay Hydropower Project in Cambodia. Targeted treatment measures are proposed according to the classification of cracks. The application of water-stopping materials, chemical grouting materials and anti-seepage coating have rendered good treatment effect, which provides a good reference for the seepage prevention treatment of cracks in concrete face slab of similar projects.